NOPS
NOPSEMA
Date not published
F214-01
32 pages
PDF
NOPSEMA approved Woodside Energy Scarborough Pty Ltd's Environment Plan for the Scarborough 4D B1 Marine Seismic Survey, an exploration petroleum activity. The assessment team concluded the EP was appropriate for the activity's nature and scale, based on: adequate activity…
-
NOPS
NOPSEMA
Date not published
F218-03
5 pages
PDF
NOPSEMA conducted an onshore inspection of Jadestone Energy (Eagle) Pty Ltd's Montara Venture facility from 2-7 February 2023 (Inspection No. 4790). The inspection verified compliance with General Direction 1886, issued 12 September 2022, which required specific actions before…
-
NOPS
NOPSEMA
Date not published
F218-02
13 pages
PDF
NOPSEMA conducted an inspection of the Montara Venture facility operated by Jadestone Energy (Eagle) Pty Ltd on 3 February 2022, reviewing Safety Case MV-70-REP-F-00004 Revision 4. The inspection report documents 15 observations and findings across multiple safety-critical…
-
NOPS
NOPSEMA
Date not published
F218-01
19 pages
PDF
NOPSEMA inspected Jadestone Energy's Montara Venture and Montara Well Head Platform during October 2021, conducting onshore assessments (26-27 October) and offshore inspections (28-31 October). The inspection examined compliance with the Montara Operations Safety Case (Revision…
-
NOPS
NOPSEMA
Date not published
F233-56
3 pages
PDF
Woodside Energy Ltd reported a notifiable incident (NTF11967) on 29 December 2022 involving a Damper Control Valve failure on the CWLH OKHA FPSO in Western Australian waters. The valve failed to meet performance standards during follow-up testing conducted after a related HVAC…
-
NOPS
NOPSEMA
Date not published
F233-55
3 pages
PDF
Woodside Energy Ltd's Vincent offshore facility in Western Australia experienced a notifiable incident (NTF11965) on 29 December 2022 when a smoke detector in accommodation room 355 was triggered by steam from a hot shower. The false alarm activated the facility's emergency…
-
NOPS
NOPSEMA
Date not published
F233-54
5 pages
PDF
Woodside Energy Ltd notified NOPSEMA of a dangerous occurrence on the CWLH OKHA FPSO (Western Australia) involving failure of a safety-critical HVAC fire damper during routine three-monthly testing on 26 December 2022. The pump room exhaust fan #3 fire damper failed to close and…
-
NOPS
NOPSEMA
Date not published
F233-53
3 pages
PDF
Woodside Energy Global notified NOPSEMA of a dangerous occurrence at the Pyrenees offshore facility in Western Australia on 20 December 2022, involving a blown fuse on pedestal crane #3 during routine cargo handling operations on 19 December 2022. The fuse failure caused the…
-
NOPS
NOPSEMA
Date not published
F233-52
4 pages
PDF
Woodside Energy Global notified NOPSEMA of a dangerous occurrence at the Pyrenees offshore facility in Western Australia on 18 December 2022. During routine maintenance function testing of a pedestal crane, the emergency lowering system failed when the manual directional control…
-
NOPS
NOPSEMA
Date not published
F233-51
5 pages
PDF
Woodside Energy Ltd reported a notifiable incident (NTF11927) at the Vincent offshore facility in Western Australia on 12 December 2022 involving structural distortion identified during a class inspection of the pump and bilge area in the engine room. The distortion, along with…
-
NOPS
NOPSEMA
Date not published
F233-50
4 pages
PDF
Woodside Energy Ltd reported a notifiable incident (NTF11920) on 10 December 2022 involving its CWLH OKHA FPSO facility off Western Australia. During inspection of a GT3 enclosure, a fire damper louvre was found dislodged from its housing, constituting a failure of performance…
-
NOPS
NOPSEMA
Date not published
F233-49
4 pages
PDF
Woodside Energy Ltd notified NOPSEMA on 5 December 2022 of a dangerous occurrence at the CWLH OKHA FPSO involving a level transmitter on the test separator that failed performance testing. During routine six-monthly calibration testing on 4 December 2022, the transmitter…
-
NOPS
NOPSEMA
Date not published
F233-48
5 pages
PDF
Woodside Energy notified NOPSEMA of a dangerous occurrence at the Pyrenees facility on 3 December 2022 when an unloaded 7-tonne crane (Crane No.4) struck a non-directional beacon antenna during scaffold removal operations on the monkey island deck. The 8-metre antenna, used for…
-
NOPS
NOPSEMA
Date not published
F233-47
5 pages
PDF
Woodside Energy Ltd notified NOPSEMA of a dangerous occurrence on 30 November 2022 involving the CWLH OKHA FPSO facility off Western Australia. Multiple level transmitters were identified with high internal damping settings that could delay sensor response and prevent Safety…
-
NOPS
NOPSEMA
Date not published
F233-46
4 pages
PDF
Woodside Energy Ltd notified NOPSEMA of a dangerous occurrence at the Okha FPSO on 26 November 2022 involving failure of low-pressure and high-pressure flare header purge flow meter alarms during routine yearly maintenance testing. The alarms failed to enunciate at their set…
-
NOPS
NOPSEMA
Date not published
F233-45
4 pages
PDF
Woodside Energy Ltd notified NOPSEMA of a dangerous occurrence at its Vincent offshore facility on 23 November 2022 involving three emergency lights in the pump room that failed routine performance testing. The lights did not meet the required discharge test time standard during…
-
NOPS
NOPSEMA
Date not published
F233-44
4 pages
PDF
Woodside Energy Global Pty Ltd reported a notifiable incident (NTF11880) at the Pyrenees offshore facility in Western Australia on 21 November 2022 involving failure of emergency lighting battery backup systems. Routine maintenance inspection discovered multiple emergency lights…
-
NOPS
NOPSEMA
Date not published
F233-43
5 pages
PDF
Woodside Energy Ltd reported a notifiable incident (NTF11871) at the Vincent facility on 19 November 2022 involving fuel gas piping defects identified during routine non-destructive testing inspections. Two Area 4 defects were found, rendering the piping not fit for service and…
-
NOPS
NOPSEMA
Date not published
F233-42
3 pages
PDF
Woodside Energy Ltd notified NOPSEMA of a non-work-related medical emergency aboard the Okha FPSO on 18 November 2022. A contractor experiencing a deteriorating non-occupational illness required evacuation; the company's emergency response plan (ERP 6.6 for serious…
-
NOPS
NOPSEMA
Date not published
F233-41
4 pages
PDF
Woodside Energy Global Pty Ltd reported a notifiable incident (NTF11862) at the Pyrenees offshore facility in Western Australia on 12 November 2022, involving severe corrosion of structural supports to a stairway on the main deck. During fabric maintenance activities, the…